Degaussing, or deperming, is the process of decreasing or eliminating a remnant magnetic field. It is named after the gauss, a unit of magnetism, which in turn was named after Carl Friedrich Gauss. Due to magnetic hysteresis, it is generally not possible to reduce a magnetic field completely to zero, so degaussing typically induces a very small "known" field referred to as bias. Degaussing was originally applied to reduce ships' magnetic signatures during World War II. Degaussing is also used to reduce magnetic fields in tape recorders and cathode-ray tube displays, and to destroy data held on magnetic storage.
The mines detected the increase in the magnetic field when the steel in a ship concentrated the Earth's magnetic field over it. Admiralty scientists, including Goodeve, developed a number of systems to induce a small "N-pole up" field into the ship to offset this effect, meaning that the net field was the same as the background. Since the Germans used the gauss as the unit of the strength of the magnetic field in their mines' triggers (not yet a standard measure), Goodeve referred to the various processes to counter the mines as degaussing. The term became a common word.
The original method of degaussing was to install electromagnetic coils into the ships, known as coiling. In addition to being able to bias the ship continually, coiling also allowed the bias field to be reversed in the southern hemisphere, where the mines were set to detect "N-pole down" fields. British ships, notably and , were well protected by about 1943.
Installing such special equipment was, however, far too expensive and difficult to service all ships that would need it, so the navy developed an alternative called wiping, which Goodeve also devised. In this procedure, a large electrical cable with a pulse of about 2000 flowing through it was dragged upwards on the side of the ship, starting at the waterline. For submarines, the current came from the vessels' own propulsion batteries. This induced the proper field into the ship in the form of a slight bias. It was originally thought that the pounding of the sea and the ship's engines would slowly randomize this field, but in testing, this was found not to be a real problem. A more serious problem was later realized: as a ship travels through Earth's magnetic field, it will slowly pick up that field, counteracting the effects of the degaussing. From then on captains were instructed to change direction as often as possible to avoid this problem. Nevertheless, the bias did wear off eventually, and ships had to be degaussed on a schedule.
Smaller ships continued to use wiping through the war. To aid the Dunkirk evacuation, the British wiped 400 ships in four days.PBS Nova "Great Escape at Dunkirk"
During World War II, the United States Navy commissioned a specialized class of degaussing ships that were capable of performing this function. One of them, USS Deperm (ADG-10), was named after the procedure.
After the war, the capabilities of the magnetic fuzes were greatly improved, by detecting not the field itself, but changes in it. This meant a degaussed ship with a magnetic hot spot would still set off the mine. Additionally, the precise orientation of the field was also measured, something a simple bias field could not remove, at least not for all points on the ship. A series of ever-increasingly complex coils were introduced to offset these fuze improvements, with modern systems including no fewer than three separate sets of coils to cancel the field in all axes.
A ferrous-metal-hulled ship or submarine, by its very nature, develops a magnetic signature as it travels, due to a magneto-mechanical interaction with Earth's magnetic field. It also picks up the magnetic orientation of the Earth's magnetic field where it is built. This signature can be exploited by magnetic mines or facilitate the detection of a submarine by ships or aircraft with magnetic anomaly detection (MAD) equipment. Navy use the deperming procedure, in conjunction with degaussing, as a countermeasure against this.
Specialized deperming facilities, such as the United States Navy's Lambert's Point Deperming Station at Naval Station Norfolk, or Pacific Fleet Submarine Drive-In Magnetic Silencing Facility (MSF) at Joint Base Pearl Harbor–Hickam, are used to perform the procedure. During a close-wrap magnetic treatment, heavy-gauge copper cables encircle the hull and superstructure of the vessel, and high electrical currents (up to 4000 ) are pulsed through the cables. This has the effect of "resetting" the ship's magnetic signature to the ambient level after flashing its hull with electricity. It is also possible to assign a specific signature that is best suited to the particular area of the world in which the ship will operate. In drive-in magnetic silencing facilities, all cables are either hung above, below and on the sides, or concealed within the structural elements of facilities. Deperming is "permanent". It is only done once unless major repairs or structural modifications are done to the ship.
To minimize this, CRTs have a copper or aluminum coil wrapped around the front of the display, known as the degaussing coil. Monitors without an internal coil can be degaussed using an external handheld version. Internal degaussing coils in CRTs are generally much weaker than external degaussing coils, since a better degaussing coil takes up more space. A degauss circuit induces an oscillating magnetic field with a decreasing amplitude which leaves the shadow mask with a reduced residual magnetization.
Many televisions and monitors automatically degauss their picture tube when switched on, before an image is displayed. The high current surge that takes place during this automatic degauss is the cause of an audible "thunk", a loud hum or some clicking noises, which can be heard (and felt) when televisions and CRT computer monitors are switched on, due to the capacitors discharging and injecting current into the coil. Visually, this causes the image to shake dramatically for a short period of time. A degauss option is also usually available for manual selection in the operations menu in such appliances.
In most commercial equipment the AC current surge to the degaussing coil is regulated by a simple positive temperature coefficient (PTC) thermistor device, which initially has a low resistance, allowing a high current, but quickly changes to a high resistance, allowing minimal current, due to self-heating of the thermistor. Such devices are designed for a one-off transition from cold to hot at power up; "experimenting" with the degauss effect by repeatedly switching the device on and off may cause this component to fail. The effect will also be weaker, since the PTC will not have had time to cool off.
Erasure via degaussing may be accomplished in two ways: in AC erasure, the medium is degaussed by applying an alternating field that is reduced in amplitude over time from an initial high value (i.e., AC powered); in Direct current erasure, the medium is saturated by applying a unidirectional field (i.e., DC powered or by employing a permanent magnet). A degausser is a device that can generate a magnetic field for degaussing magnetic storage media. The magnetic field needed for degaussing magnetic data storage media is a powerful one that normal magnets cannot easily achieve and maintain.
For certain forms of computer data storage, however, such as modern hard disk drives and some , degaussing renders the magnetic media completely unusable and damages the storage system. This is due to the devices having an infinitely variable read/write head positioning mechanism which relies on special servo control data (e.g. Gray Code) that is meant to be permanently recorded onto the magnetic media. This servo data is written onto the media a single time at the factory using special-purpose servo writing hardware.
The servo patterns are normally never overwritten by the device for any reason and are used to precisely position the read/write heads over data tracks on the media, to compensate for sudden jarring device movements, thermal expansion, or changes in orientation. Degaussing indiscriminately removes not only the stored data but also the servo control data, and without the servo data the device is no longer able to determine where data is to be read or written on the magnetic medium. The servo data must be rewritten to become usable again; with modern hard drives, this is generally not possible without manufacturer-specific and often model-specific service equipment.
/ref>
Degaussing range
High-temperature superconductivity
Early experiments
Color cathode-ray tubes
Magnetic data storage media
Irreversible damage to some media types
Tape recorders
Types of degaussers
Electromagnetic degaussers
Rotating coil degausser
Pulse degaussing
Permanent magnet degausser
See also
External links
|
|