Time of flight ( ToF) is the measurement of the time taken by an object, particle or wave (be it acoustic, electromagnetic, etc.) to travel a distance through a medium. This information can then be used to measure velocity or path length, or as a way to learn about the particle or medium's properties (such as composition or flow rate). The traveling object may be detected directly (direct time of flight, dToF, e.g., via an ion detector in mass spectrometry) or indirectly (indirect time of flight, iToF, e.g., by light scattered from an object in laser doppler velocimetry). Time of flight technology has found valuable applications in the monitoring and characterization of material and biomaterials, hydrogels included.
For magnetic resonance angiography (MRA), ToF is a major underlying method. In this method, blood entering the imaged area is not yet saturated, giving it a much higher signal when using short echo time and flow compensation. It can be used in the detection of aneurysm, stenosis or dissection.
In time-of-flight mass spectrometry, ions are accelerated by an electrical field to the same kinetic energy with the velocity of the ion depending on the mass-to-charge ratio. Thus the time-of-flight is used to measure velocity, from which the mass-to-charge ratio can be determined. The time-of-flight of electrons is used to measure their kinetic energy. Time-of-Flight Techniques For The Investigation Of Kinetic Energy Distributions Of Ions And Neutrals Desorbed By Core Excitations
In near-infrared spectroscopy, the ToF method is used to measure the media-dependent optical pathlength over a range of optical wavelengths, from which composition and properties of the media can be analyzed.
In ultrasonic flow meter measurement, ToF is used to measure speed of signal propagation upstream and downstream of flow of a media, in order to estimate total flow velocity. This measurement is made in a collinear direction with the flow.
In planar Doppler velocimetry (optical flow meter measurement), ToF measurements are made perpendicular to the flow by timing when individual particles cross two or more locations along the flow (collinear measurements would require generally high flow velocities and extremely narrow-band optical filters).
In optical interferometry, the pathlength difference between sample and reference arms can be measured by ToF methods, such as frequency modulation followed by phase shift measurement or cross correlation of signals. Such methods are used in laser radar and laser tracker systems for medium-long range distance measurement.
In neutron time-of-flight scattering, a pulsed monochromatic neutron beam is scattered by a sample. The energy spectrum of the scattered neutrons is measured via time of flight.
In kinematics, ToF is the duration in which a projectile is traveling through the air. Given the initial velocity of a particle launched from the ground, the downward (i.e. gravitational) acceleration , and the projectile's angle of projection θ (measured relative to the horizontal), then a simple rearrangement of the SUVAT equations
results in this equation
for the time of flight of a projectile.
Optical time-of-flight sensors consist of two light beams projected into the fluid whose detection is either interrupted or instigated by the passage of small particles (which are assumed to be following the flow). This is not dissimilar from the optical beams used as safety devices in motorized garage doors or as triggers in alarm systems. The speed of the particles is calculated by knowing the spacing between the two beams. If there is only one detector, then the time difference can be measured via autocorrelation. If there are two detectors, one for each beam, then direction can also be known. Since the location of the beams is relatively easy to determine, the precision of the measurement depends primarily on how small the setup can be made. If the beams are too far apart, the flow could change substantially between them, thus the measurement becomes an average over that space. Moreover, multiple particles could reside between them at any given time, and this would corrupt the signal since the particles are indistinguishable. For such a sensor to provide valid data, it must be small relative to the scale of the flow and the seeding density. MOEMS approaches yield extremely small packages, making such sensors applicable in a variety of situations.
The work function homogeneity of the tube can be controlled by a Kelvin probe. The magnetic field can be measured by a fluxgate compass. High frequencies are passively shielded and damped by radar absorbent material. To generate arbitrary low frequencies field the screen is parted into plates (overlapping and connected by capacitors) with bias voltage on each plate and a bias current on coil behind plate whose flux is closed by an outer core. In this way the tube can be configured to act as a weak achromatic quadrupole lens with an aperture with a grid and a delay line detector in the diffraction plane to do angle resolved measurements. Changing the field the angle of the field of view can be changed and a deflecting bias can be superimposed to scan through all angles.
When no delay line detector is used focusing the ions onto a detector can be accomplished through the use of two or three placed in the vacuum tube located between the ion source and the detector.
The sample should be immersed into the tube with holes and apertures for and against stray light to do magnetic experiments and to control the electrons from their start.
|
|