Total Dissolved Gas And Water Temperature In The Lower Columbia River, Oregon And Washington, Water Year 2009: Quality-assurance D
 (

ISBN 9781288708086
REGISTERED: 02/18/23
UPDATED: 02/08/26
Total Dissolved Gas And Water Temperature In The Lower Columbia River, Oregon And Washington, Water Year 2009: Quality-assurance D

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases


Specifications
  • Total Dissolved Gas And Water Temperature In The Lower Columbia River, Oregon And Washington, Water Year 2009: Quality-assurance D available on January 31 2017 from Indigo for 20.5
  • ISBN bar code 9781288708086 ξ1 registered January 31 2017
  • Product category is Book

  • # 978128870808

Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight monitoring stations on the lower Columbia River in Oregon and Washington in 2009. Significant findings from the data include: During the spill season of April through August 2009, hourly values of total dissolved gas (TDG) were occasionally larger than 115-percent saturation for the forebay stations (John Day navigation lock, The Dalles forebay, Bonneville forebay, and Camas). Hourly values of total dissolved gas were occasionally larger than 120-percent saturation for two tailwater stations (John Day Dam tailwater and Cascade Island). From mid- to late July to mid-September 2009, water temperatures were greater than 20 degree(s) C (degrees Celsius) at seven stations on the lower Columbia River. According to the State of Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20 degree(s)C; Washington regulations state that the 1-day maximum should not exceed 20 degree(s) C as a re-sult of human activities. All 96 laboratory checks of the TDG sensors with a certified pressure gage were within 0.4 percent saturation after 3 to 4 weeks of deployment in the river. All but 2 of the 73 in situ field checks of TDG sensors with a secondary standard were within or - (plus or minus) 1.0-percent saturation after 3-4 weeks of deployment in the river. All 74 of the field checks of barometric pressure were within or - 2.0 millimeters of mercury of a secondary standard, and all 65 water-temperature field checks were within or - 0.2 degree(s) C. For the eight monitoring stations in water year 2009, a total of 99.2 percent


References
    ^ Total Dissolved Gas And Water Temperature In The Lower Columbia River, Oregon And Washington, Water Year 2009: Quality-assurance D Indigo. (revised Jan 2017)

Page 1 of 1
1

Account

Social:
Pages:  ..   .. 
Items:  .. 

Navigation

General: Atom Feed Atom Feed  .. 
Help:  ..   .. 
Category:  ..   .. 
Media:  ..   .. 
Posts:  ..   ..   .. 

Statistics

Page:  .. 
Summary:  .. 
1 Tags
2/10 Page Rank
6 Page Refs
9s Time
32 Sources